GLP-3 (RT)30 mg vial
In stockChromatographic purity
- Lot number0013-B
- MethodHPLC-UV/VIS
- Laboratory IDV260728-13 001
- Date reported
- Vial label reads#0013-RETA
- IdentityPass, matches reference standard
Certificate library
9 certificates across 4 compounds, every one issued by Vanguard Laboratory of Olympia, Washington. Read them before you order.
Holding a vial? Type the batch code printed on its label to open that exact certificate.
Chromatographic purity
Chromatographic purity
Chromatographic purity
Chromatographic purity
Outcome. Below our 99+% acceptance threshold. This batch was rejected and never listed for sale.
Lot field. The certificate records the lot as 013. The Alphex batch number for the same submission is 0013.
Chromatographic purity
Chromatographic purity
Chromatographic purity
Lot field. The laboratory recorded this submission under the sample marking Red Cap rather than the Alphex batch number. The vial label for this batch reads #0010-BPC.
Chromatographic purity
Chromatographic purity
Check the batch string on the vial label, or email our team with the code and we will find it.
All testing is carried out by Vanguard Laboratory, 2635 Parkmont Ln, Olympia, WA 98502. Vanguard is accredited to ISO/IEC 17025:2017 by A2LA under certificate scope 6377.01. The chromatographic purity results shown here are not represented as accredited-scope tests. Consult A2LA Certificate 6377.01.01 for the list of accredited tests.
Each certificate states its own limitations, which we repeat here rather than bury: the laboratory did not observe or participate in the sample selection process, and cannot confirm the authenticity of the sample or its representativeness of the associated lot or batch. Results relate only to the portion of the sample tested.
Certificates marked Superseded are earlier lots that are no longer shipping. They stay published so the record is complete. A certificate marked Rejected is a batch that failed our acceptance threshold and was never listed for sale. We publish those too.
Our testing covers chromatographic purity, and identity where the certificate states it. It does not cover endotoxin, water content, heavy metals or sterility, except on bacteriostatic water where sterility is tested. All products are supplied for laboratory and in-vitro research only, and are not authorised for human or veterinary use.