Certificate library

The laboratory report behind every batch

9 certificates across 4 compounds, every one issued by Vanguard Laboratory of Olympia, Washington. Read them before you order.

Holding a vial? Type the batch code printed on its label to open that exact certificate.

GLP-3 (RT)30 mg vial

In stock

Chromatographic purity

>99.80% ± 0.18%
  • Lot number0013-B
  • MethodHPLC-UV/VIS
  • Laboratory IDV260728-13 001
  • Date reported
  • Vial label reads#0013-RETA
  • IdentityPass, matches reference standard

GLP-3 (RT)20 mg vial

In stock

Chromatographic purity

>99.80% ± 0.18%
  • Lot number0013-A
  • MethodHPLC-UV/VIS
  • Laboratory IDV260724-8 001
  • Date reported
  • Vial label reads#0013-RETA
  • IdentityPass, matches reference standard

GLP-3 (RT)30 mg vial

Superseded

Chromatographic purity

99.70% ± 0.18%
  • Lot number0013-A
  • MethodHPLC-UV/VIS
  • Laboratory IDV260724-8 002
  • Date reported
  • Vial label reads#0013-RETA
  • IdentityPass, matches reference standard

GLP-3 (RT)30 mg vial

Rejected

Chromatographic purity

83.48% ± 0.18%
  • Lot number0013
  • MethodHPLC-UV/VIS
  • Laboratory IDV260526-45 002
  • Date reported
  • Vial label readsnot shipped

Outcome. Below our 99+% acceptance threshold. This batch was rejected and never listed for sale.

Lot field. The certificate records the lot as 013. The Alphex batch number for the same submission is 0013.

GLP-3 (RT)5 mg vial

Superseded

Chromatographic purity

>99.80% ± 0.18%
  • Lot number0011
  • MethodHPLC-UV/VIS
  • Laboratory IDV260226-3 001
  • Date reported
  • Vial label reads#0011-RETA

GLP-3 (RT)5 mg vial

Superseded

Chromatographic purity

>99.80% ± 0.18%
  • Lot number0010
  • MethodHPLC-UV/VIS
  • Laboratory IDV250909-14 001
  • Date reported
  • Vial label reads#0010-RETA

BPC-1575 mg vial

In stock

Chromatographic purity

>99.80% ± 0.18%
  • Lot numberRed Cap
  • MethodHPLC-UV/VIS
  • Laboratory IDV260226-3 002
  • Date reported
  • Vial label reads#0010-BPC

Lot field. The laboratory recorded this submission under the sample marking Red Cap rather than the Alphex batch number. The vial label for this batch reads #0010-BPC.

GHK-Cu50 mg vial

In stock

Chromatographic purity

>99.80% ± 0.18%
  • Lot number0010
  • MethodHPLC-UV/VIS
  • Laboratory IDV251215-25 001
  • Date reported
  • Vial label reads#0010-GHK

Bacteriostatic Water10 mL vial

In stock

Chromatographic purity

Pass on all three assays
  • Lot number0010
  • MethodHPLC-UV/VIS, AOAC 981.12, USP <71>
  • Laboratory IDV251215-25 002
  • Date reported
  • Vial label reads#0010-BAC
  • Benzyl alcohol0.89%, within the 0.72 to 1.08% limit
  • pH6.35, within the 4.0 to 7.0 limit
  • SterilityNegative, no growth

About these certificates

All testing is carried out by Vanguard Laboratory, 2635 Parkmont Ln, Olympia, WA 98502. Vanguard is accredited to ISO/IEC 17025:2017 by A2LA under certificate scope 6377.01. The chromatographic purity results shown here are not represented as accredited-scope tests. Consult A2LA Certificate 6377.01.01 for the list of accredited tests.

Each certificate states its own limitations, which we repeat here rather than bury: the laboratory did not observe or participate in the sample selection process, and cannot confirm the authenticity of the sample or its representativeness of the associated lot or batch. Results relate only to the portion of the sample tested.

Certificates marked Superseded are earlier lots that are no longer shipping. They stay published so the record is complete. A certificate marked Rejected is a batch that failed our acceptance threshold and was never listed for sale. We publish those too.

Our testing covers chromatographic purity, and identity where the certificate states it. It does not cover endotoxin, water content, heavy metals or sterility, except on bacteriostatic water where sterility is tested. All products are supplied for laboratory and in-vitro research only, and are not authorised for human or veterinary use.